Emc vnx 5200 default ip address

Emc vnx 5200 default ip address

emc vnx 5200 default ip address Re SRM 5 EMC VNX 5300 Setup Array Manager. On the Analytics probe server home page click Add Probe. Go to https Support. The default is quot nasadmin. x . 502 and later May 15 2012 EMC Secure Remote Support ESRS firewall configuration. When adding a system into the domain the system being added will be removed from any of its existing domain configurations. Cisco UCS Director EMC VNX Management Guide Release 5. However the XML API server is disabled by default. admin Password123 14 EMC VNX for File Simulator Installation and Configuration Guide V7. Type IP address es of the NTP servers. May 08 2018 EMC VMAX Storage System VMAX40K VMAX 1 VMAX20K VMAX100K VMAX 1SE EMC VMAX probe EMC VNX Block Storage VNX 5200 VNX 5700 EMC VNX File probe EMC VNX File Storage VNX 5200 EMC VNX Block probe EMC XtremIO Storage XtremIO Storage Array 4. 0. 1 will appear under Hosts gt Host List as well. 248 Default Gateway 128. Specify Storage Name or Address and Storage Role. 0 10. IP address The IP address or fully qualified domain name of the Isilon cluster User Name User name for the Isilon cluster Password Password used for the Isilon cluster Advanced configuration Field Description Inventory Poll Interval min Interval between inventory polls. 201 SPB Change CS0 IP address and verify a Change the IP address on CS0 to the new network address and verify This information includes A static IP address for each storage processor in the system for example 123. 72 CONNECTION vROps hostname or IP address File Primary Control Station Command Line Interface CLI via SSH on default SSH port 22 Mar 05 2014 Start Search iSCSI Initiator. 16. com . 6. The port number at which the storage device listens. It enables administrators to view manage and optimize storage for VMware ESX ESXi servers and hosts and then map that storage to the hosts. EMC VNX Series Configuring and Managing Networking on VNX. May 26 2011 Understanding the EMC VNX Celerra AntiVirus Agent CAVA Part 1 server_viruschk. 1. 32 or higher. Now Connect to the pairs like a4 b4 and a5 b5 whichever is assigned. Set it to vnx for the VNX driver. 17. The SMI S provider listens on port 5988 HTTP and 5989 HTTPS by default so wherever Oct 17 2013 By default it is opt VNX which is good. Note EMC supports CLARiiON and VNX systems only up to version 4. Apr 02 2000 The solution leverages the EMC SMI S Provider for VNX CLARiiON and VMAX Symmetrix systems that needs to be installed on a Windows or Linux system. 255. Register the wwn with more ports if needed. 0 Support 4 Executive summary EMC VNX has incorporated the Server Message Block SMB protocol as an open standard for network file service. If it first asks to save the certificate choose option 2 EMC Unisphere Unified Storage Management Solution for theVNX2 Series 10 A Detailed Review Enterprise Dashboard System List The System List provides details for all the storage systems in your storage environment including IP address serial number health status software revision and more. VMware Tools 10. Enter Storage credentials as Username sysadmin and password sysadmin. Login using default username password i. The IP address of the storage device for which this test is to be configured. Unity nas failover Cisco Catalyst 9300L Network Essentials Switch L3 managed 48 x 10 100 1000 PoE Default Collection Frequency Storage processor ip address. 0. 5 bypassing quot unknown_ca quot error August 3 Trend Micro Deep Security 9. 241. Next select the type of LUN thin or Oct 12 2018 Type in the IP address of Storage Processor A and Storage Processor B if Clariion. Note If the host is not powered on we will not see it in our hosts available. Make sure EMC Control Station can ping NTP server IP Changing IP address of a host in Navisphere 6 EMC array We have a EMC CX4 120 array and manage it using Navisphere 6 web interface. Type 2 Type 2 Type the username type a user that has at least a read access on the CLARiiON VNX Array Type the password password of the above user Then type enter Name used to log in to the VNX device. emc_nas_server_container Apr 23 2015 EMC VNX List of Useful NAS Commands. Note This health check ensures that there are no major errors in the Download the . pnCollector. Control Station Port. Confirm that the script Timeout value is set to 30 seconds in the zabbix_server. 1. Reconfigure management port via W2K8 desktop. VNX IP Celerra IP address The default is 40. Add a default route by typing sbin route add default gw 172. 0 and NSX If the password is lost you must redeploy the Solutions Integration Service and use the default login ID and password to log in. 015 VNX OE for File 8. So connect to the Isilon cluster over that IP address making sure you end up on node 1. Jan 26 2015 EMC VNX ArrayConfig amp SPCollect Powershell Script SPCollect The naviseccli spcollect command selects a collection of system log files and places them in a single . Then run the following command support connectemc device register lt IP ADDRESS DD gt esrs gateway lt DNS hostname not FQDN of SRS server gt . SMB is a file access protocol designed for the internet and is based on the Common Internet File System CIFS protocol that the Aug 24 2020 VNX IP address amp Credentials to the Celerra Control Station. SRM Support for Air inlet Temperature of EMC VNX 5200 . 10. This section has several entries and is where we configure all the domain information. xxx. xxx SPB IP Address of the CLARiiON VNX Array Type enter. 101. kastlr Nov 24 2011 5 37 AM in response to IanTech Hi by default. Only local users of VNX File is supported. xxx SPB IP Address of the CLARiiON VNX Array Type enter. EMC. 0. Apr 20 2017 ssh lt navicli user gt lt navicli host ip gt naviseccli User sysadmin Password lt sysadmin pass gt Scope 0 Address lt SP A IP gt port list Step 10 Enter the password at the login prompt after accepting the SSH certificate It should list VNX Storage Array port configuration. D. The prefix length should be appended to the IPv6 address and if omitted will default to 64. 1 Click Register. Next assign the subnet mask and then click ok and close out of the network preferences. However the VNX is not as simple. C. Mixed protocol environments can be complex to manage but if you have a required use case it s better to setup it properly ahead of time than mid production use. xx. Specify the IP address of the storage controller on the block only storage system in the Controller IP text box. IP address filtering is not installed by default. Mar 09 2018 The plug in name. 63 1. However XenServer does not include this capability in their feature set and is unable unwilling to include it in their custom Linux kernel at this time. Select Software because we are installing Enabler. After you power up the VNXe system check the SP Fault Status LEDs If the SP Fault Status LEDs are solid blue a management IP address has been assigned EMC VNXe2 Series VNXe3200 Installation Guide To configure ESRS the DNS should already be configured. To the best of my knowledge the configuration of the VSI couldn 39 t be changed so you need to Feb 10 2016 Integration for Zabbix and the EMC ECOM server for VNX1 VNX2 Monitoring ktelep EMC Zabbix Integration A point in time copy of a production environment can be replicated asynchronously to a remote VNX and in the event of disaster can be accessed using the same CIFS servers share names and local groups. How to Shutdown or Power off Emc VNX 5200 5500 Storage Default Passwords Navicli does not require a reboot of the SP after changing the SP IP address but Storage Processor Cache Test. Metric Group Nov 15 2016 Depending on how IP addressing has been assigned open a browser and enter the IP address manually configured or the DNS entry serialnumber. Here are the steps. 1. By default the username is vnx but you can make it anything you like. Figure 33 on page 86 illustrates the minimum configuration for an ESXi host with two network cards. Security policy settings apply to VNXe vVNX Dell EMC Unity and Dell EMC UnityVSA systems only. Enter the account name and password and then click OK. Here is Your Customized Document Your Configuration is Manage storage pools Model VNX5200 Storage Type VNX for Block SAN Connection Type Fibre Channel Switch or Boot from SAN Operating System ESX Server 4i Path Management Software VMware native Document ID 1417800073399 Reporting Problems To send comments or report errors regarding this document please email mydocs emc. 241. Generally once warranty terms and finance expire old SANs like this get returned to sender to be replaced by EMC VNX Virtual Network Device Configuration with Unisphere In prior sections of this lab not applicable if you are doing this as a stand alone lightning lab you may have configured and presented storage to ESXi servers using the VSI plugin for vCenter. Aug 22 2011 On July 14 th EMC has released ETA emc263721 powerlink credentials required to address this issue. x of the SMI S Provider Solutions Enabler v7. The default settings are port 443 on the VNX Storage Processors and port 5989 on the VNX Control Station. Follow the wizard to set up the ESRS and test the ConnectHome process. the virtual appliances are configured to accept secure connections only and. OpsRamp uses XML API server to discover and monitor an EMC VNX device. 221. The following procedure explains in details how to get install and configure EMC SMI S Provider to enable TrueSight Operations Management EMC Storage Monitoring to efficiently interact with it. Username sysadmin. IP address filtering does not restrict any access. This option was introducted in the operating system version 2. In case you use a local account then select the option Local. Installation. Through the Unisphere GUI Settings gt Service System gt Select Shutdown and click Execute Service action. 33. For VNX Block Systems traditional LUN based storage arrays Perform an SP Collect for each Storage Processor Access either SPA or SPB from a system that can manage the array and login. IP address filtering prevents all communications until the VNX system is configured. emc_nas_password and emc_nas_login. If there is another admin account on the system try using May 29 2017 Default Passwords Here is a collection of default password to save you time googling for them EMC Secure Remote Support ESRS Axeda Policy Manager Server Username admin Password EMCPMAdm7n EMC VNXe Unisphere EMC VNXe Series Quick Start Guide step 4 Username admin Password Password123 EMC vVNX Unisphere Username admin Password Password123 NB You must change I m surprised that I haven t done an article on configuring Active Directory AD authentication on the VNX. Jun 26 2015 Before proceeding ensure you have the both VNX Storage Processor A amp B IP addresses to hand the SMI S host will use these IP s to allow for out of band communication over IP with the VNX. These arrays use SMI S file and XML API file performance . verification most secure default and Dell EMC recommended . 08 27 2018 09 37 PM Tagged Why can I not retrieve vnx file data from EMC VNX 5200 when using Splunk Add on for EMC VNX on All Apps and Add ons. There are two basic rules to implement this solution first is you have to use VNX Replicator. Those are basics steps to actually privision the storage from EMC VNX. Some time in the past we have registered all the HBA of 5 different hosts. Number of Celerra command retry attempts. Confirm that it is OK to continue. For IPv4 addresses the default length is 24. 33. Entering multiple server names or IP addresses will result in events being sent in a round robin fashion to configured CEE servers and as such not all events will be received by all CEE servers. The communication that leverages EMC Data Domain Boost can go over the LAN or FC as indicated Apr 16 2021 IP Address Manager IPAM User Device Tracker UDT SRM Support for Dell EMC PowerStore. rpm The IP address of the storage device for which this test is to be configured. Specify the IP address of the storage controller on the block only storage system in the Controller IP text box. For up to 10 storage systems we need 8 CPU cores and 32 GB RAM. Username and password. 2. 6. We 39 ve had EMC provide us the documentation and had them assist with the password reset procedure as there were complications along the way. CIFS DR solution is asynchronus. 13. When patching VNX iSCSI ports make sure to NOT use the ports claimed by MirrorView. B. EMC recommends that VNX MirrorView ports. Important The SPCollect functionality can affect system performance may This information includes l A static IP address for each storage processor in the system for example 123. Max 1 GBaseT Ports per X Blade 8 8 8 12 12 16 Max 10 GbE Ports per X Blade 4 4 4 6 6 8 Feb 16 2019 Unable to access CIFS share folder on windows host using IP Address EMCVnxe3150. Server and Port Initiator IP Address Subnet Mask Default gateway Table 1010Content required for ESRS setup VNX System Storage Processor Select the system SP to manage ESRS support EMC Support Credentials Account login information Username Password Use these credentials to configure ESRS. The VNX series is designed for a wide range of environments that include mid tier through enterprise. 250 . We recommend that you break large data sets into smaller divisions and repeat this procedure until all of the data is migrated. 6 vSphere 6. 1. Default Gateway Enter the default gateway IP address 192. Be sure to remove any characters in the hyperlink following . Login with username service refer EMC documentation for password . Note The system uses the first IP address you specify. Aug 24 2020 DELL EMC VNX File formerly Celerra Unified Storage System data collector 08 24 2020 Contributors Download PDF of this page This data collector acquires inventory information from the VNX File Storage System. If the machine has more than one IP address you need to be careful. . Aug 01 2011 Configuring LDAP on VNX for FILE. Provide the management interface IP Address. X Block Navisphere Secure Command Line Interface NaviSecCLI Revision 7. Controller IP. If there s a MirrorView enabler installed it will claim itself the first FC port and the first iSCSI port. Oct 08 2012 Hello Experts I wonder what is the default Ip Adress of an EMC VNX Storage. e. Open It Discovery. Type the array id for Storage Processor A and Storage Processor B if Symmetrix. 7 The IPv6 global prefix and gateway for each SP if your network supports the IPv6 Internet Protocol and you want to manually configure IPv6 for the management ports The subnet mask of the LAN to which the system is connected The default gateway address of the LAN to which the system is connected 8 EMC VNX5200 Block Installation Guide Unpack your system Unpack and Nov 15 2013 This is a guideline on how to change the VNX Storage Processor IP and Name via Navicli. EMC VNXe. 1. Username User name to log on to the VNX file storage. Log out iSCSI on the node Aug 16 2019 The plug in name. AX4 5. Click on Discover Portal. Navicli does not require a reboot of the SP after changing the SP IP address but does require a restart of the Management Server. 08 28 2018 12 18 AM. 221. Edit the network configuration file etc sysconfig network scripts ifcfg eth3 by using a text editor. The control station IP address of the VNX system to be managed. Username sysadmin. The options are 30 mins default 1 hour 4 hours 12 hours 1 day 7 days 30 days. useUnixGid 0x00000001 0x00000000 This article explains how to install and configure the EMC SMI S provider to monitor the Dell EMC CLARiiON disk arrays with the Hardware and Storage Monitoring solutions developed by Sentry Software. emc. 2 . Add the new gateway IP address for the entries similar to DEVICE eth3 Mar 22 2019 We recently purchased a VNX 5300 at auction and would like to reinitialize to factory default we are new to the EMC world. Field. Akhi Gupta. 254 Subnet Mask 255. If the system has multiple IP addresses use the address by which the Data Protector ZDB agent can access the system. First you need to give a SPA or SPB IP address and provide the authentication method. The IP address of the storage device for which this test is to be configured. 0. 255. If necessary edit the etc netmasks file to add any missing entries. 12949. The default is NULL. Install the Splunk Add on for EMC VNX. DELL EMC Data Domain Management Center https lt DDMC Name or IP Address gt ddmc . There are complexities when working with a mixed protocol environment which is a result of EMC VNX Series Introduction to SMB 3. It should be used in conjunction with the Add your storage array for monitoring with SRM topic in the Success Center documentation or online help. 0 24 subnet. Storage Processor Info. Jul 19 2012 The EMC Whitepaper on VNX Best Practices h8268_VNX_Block_best_practices. This should help Installing and Configuring EMC SMI S Provider and Solutions Enabler Appliance VNX CLARiiON just follow the instructions for installing and configuring the provider . EMC supports Symmetrix VMAX3 systems only in version 8 or higher of the SMI S Provider and Solutions Enabler. Tiering should be set to quot Auto quot as it will automate fail over process. 5. 45. The default is 20. Unity nas failover Cisco Catalyst 9300L Network Essentials Switch L3 managed 48 x 10 100 1000 PoE Filtered IP Addresses. br on Configuring VASA for use with a VNX What you need to know about vSAN 7. 110. The data collector is able to run NaviCLI NaviSecCLI commands against the backend array utilizing the DART OS NAS heads Jul 24 2015 Unisphere VNX Client EMC Unisphere VNX Client commonly referred to as Unisphere off array is the locally installed host based version of Unisphere. It means that during the failure you will loose some data. Jul 31 2019 net host add 10. Dec 03 2013 Configure VNX for NDMP. . Once you have the SMI S provider installed and you have added your arrays adding the VNX in solarwinds is very easy you will be prompted to add the IP where Navisphere CLI is a tool provided by EMC to provide for programmatic management of block SAN storage systems such as Clariion and VNX series. 101. 33 MB PDF This Chapter 1. 1 quot Wait and log into web interface on VNXe and disable SSH. The Networker side of things is already concisely documented here under the heading Adding a NAS filesystem to backup using NDMP In order for NDMP backups to work some configuration of the VNX is necessary. rpm file directly to the Collector host using the following command curl user email address password O L rpm file URL NOTE The rpm file URL can be copied by right clicking on the Navisphere CLI version for Linux x64 link. xxx. . Right click EMC VNX CLARiiON Storage System and click Properties. PDF Complete Book 2. Enter the IP address of Storage in USM. Enter IP Address of the primary Control Station of the EMC VNX Device Enter Username and Password API credentials of the Control Station Unisphere credentials Alternatively you can use zenbatchload to add VNX VMAX file storage from the command line. Do not enter multiple server names or IP addresses. In the DNS name or IP address field specify a DNS name or Dell EMC Hopkinton Massachusetts 01748 9103 1 508 435 1000 In North America 1 866 464 7381 2 eNAS CLI Reference Guide 8. Download it from EMC support page Mar 08 2016 VNX Monitoring and Reporting automatically collects block and file storage statistics along with configuration data and stores them into a database that can be viewed from dashboards and reports. xxx. emc_nas_password and emc_nas_login fields are used to provide credentials to the VNX system. The EMC CAVA Properties Local Computer dialog appears. 26 Using EMC VNX Storage with VMware vSphere TechBook Configuring VMware vSphere on VNX Storage fast clone of a master image and then register the fast clone image with virtual desktop clients. 0. Default login password for EMC VNX Unified system is login sysadmin password sysadmin. 254. It s not scalable. 1. X IP Address. What we are able to do Connect to Remotely Anywhere via service port. The provider translates data from the array into a unified format based on CIM classes. Find more similar flip PDFs like Configuring Time Services on VNX EMC. Mar 05 2013 There are two ways you can shutdown the VNXe. Download PDF. EMC Clariion VNX Template. It also handles all RAID operations as well as read and write caching. 25. I am asking this question because when you want to configure an EMC VNX for the first time with the connection utility tool your laptop as to be in the same lan as the storage. Click Apply. Select your legacy EMC product to get started. Then host 10. Next assign the subnet mask and then click ok and close out of the network preferences. In the IP Address Allocation step choose the IP allocation policy and IP On the Ethernet port manually configure the IP and make it something close to the two IP addresses you will be assigning to the VNX. A default IP address pool is configured during the initial cluster setup through the command line configuration wizard. 10. 5 as it is the most current one available. EMC SMI S provider is included as part of Solutions Enabler with SMIS install package which can be downloaded from support. Roughly you might count 2 30 GB per a storage it depends on number of volumes 30GB for 5000 volumes df g home AIX df h home Linux. 252. 61. Using this process you can deploy multiple XenDesktop or Horizon View virtual desktops from a single image in minutes. emc_nas_server_container field is the name of the Data Mover to serve the share service. 08 27 2018 09 37 PM Jun 04 2012 Overview. xxx. Set it to vnx for the VNX driver. 248. Dec 08 2012 Last week I had to change the default gateway for an EMC VNX5300 storage system. Apr 22 2016 Edit the emc_vnx_stats. Control Station IP. Thank you. You can make changes to the primary not standby. The Default Owner of the Disk Volume. Configuration file. It offers plenty of different disk and connectivity combinations in a single storage appliance hence it being termed Unfied storage . May 28 2012 Tick Enable NTP and select time synchronization interval from the drop down menu. The default authentication method is Global. 249 or 128. If there is any possibility of file systems ever being replicated then the VNX servers involved should share a single primary Usermapper service. Aug 18 2011 Hands on with VNXe 3300 Part 1 Initial setup. Press Y to install to the directory specified. 6. 3. Install VNX CLI for the Splunk Add on for EMC VNX. you also need to go to the properties of each storage processor A B and configure a prvilidged user account for each hyper v host system ip of hyperv host HYPER V Hosts . Perform the following steps to automatically assign an IP address to your VNXe system management port Procedure 1. Traditionally a user would open a browser and connect to the IP address of the storage system. co emc vnx and celerra virtual storage appliance vsa free download link. 7 l The IPv6 global prefix and gateway for each SP if your network supports the IPv6 Internet Protocol and you want to manually configure IPv6 for the management ports l The subnet mask of the LAN to which the system is connected l Oct 09 2019 lt CEE server name or IP address gt is the name or IP address of the CEE server. com. To add a VNX system into an existing VNX local domain in Unisphere navigate to the System List and perform Add operation. xxx SPB IP Address of the CLARiiON VNX Array type enter. Please note that a change of SP Name will require a reboot of the SP. xxx. Apr 14 2015 The pixelation is masking it but this shows that the default self signed certs have the ip address and not the hostname in the SUBJECT. Configuring VMware vSphere on VNX Storage 3. Click the Log On tab. However if you use LDAP authentication then select LDAP. I have already researched the instructions for viewing the certificate and regenerating a new one. 255. 9. 255. First Login. Jan 31 2013 Usermapper Usermapper is a vnx service that authomatically generates and maintains a database that maps SIDs to UIDs abd GIDs for users or groups accessing file systems from Windows domain. VNX provides offering that file only block only and unified block and file implementations. I found the cause. Access validation Run NaviSecCLI from the Cloud Insights AU to each array using the username and password. Set it to vnx for the VNX driver. 6. You can configure up to ten NTP servers maximum. Download Full PDF Package. Here is the diagram for you Any firewall admin of course will not be happy to open ports 443 and 8443 to all servers on the Internet. Enter VNX Credentials. CX4. It s pretty easy to do and a good idea. Enter the IP address. The IP address pool of a subnet consists of one or more IP address ranges and a set of cluster interfaces. Now iSCSI connector is ready on the Windows Server 2012 R2 Aug 28 2012 EMC VNX Celerra NAS Multiprotocol Environment Planning. Nov 18 2016 Best Practices for EMC VNX VNXe and Data Domain with Veeam Availability Suite 22 2016 Veeam Software The system name is the DNS name orTCP IP address of the Data Domain server that will house the DD Boost Storage Unit connected in the previous steps. http techhead. Events generated from these IP addresses will be filtered. You have to provide an SP Storage Processor IP address of the VNX system to be added. xx Storage Processor Gateway Address 10. Switch Port amp IP Address Management Mar 23 2012 VNX management IP address and credentials Note If storage zoning is not complete obtain the HBA World Wide Names WWNs from the SAN switch. Verify status of Control station. 2. Read only username and password. You ll automatically be presented with the startup wizard. Dec 23 2019 After the Solutions Integration Service password is changed it cannot be modified. If the sysadmin password is lost or unknown but you can ssh to the control station and log on as nasadmin then you can run the following commands to view any additional admin accounts if any were created . We need to choose the one which is highlighted This will log all the targets on the EMC VNX box to mapped . Cisco Integrated Management Controller IMC CIMC BMC Username admin. Doing so lets the Connection Utility automatically detect the new storage Aug 16 2019 Click the Register button select CLARiiON VNX and enter the host name which is the output of the hostname command and IP address Hostname myhost1 IP 10. emc_nas_server is the control station IP address of the VNX system to be managed. Then host 10. Run the Connection Utility from a host attached to the same subnet as your storage system. 0. Aug 26 2012 Blades Check if Blade parameters use EMC default values Information HC_DM_27390050398 The following parameters do not use the EMC default values Mover_name Facility_name Parameter_name Current_value Default_value server_2 cifs acl. Feb 02 2018 To launch a Unisphere you can fire up an Internet browser and type the IP address of either one of the SPs or the Control Station. Controller IP. We have an EMC VNX 5300 and the certificate has expired. 5 Apr 10th 2017 README Types Puppet VNX Module Puppet VNX module wraps Naviseccli into Puppet module to simplify the configuration of VNX Initiator DNS Storage Pool Hot Spare Storage Group LUN Fast Cache NTP Domain SP and Array. EMC VNXe3150 VNXe3300. August 7 2012 admin Leave a comment. Configure each adapter with an IP address from a separate network subnet. In the VNX File Probe Details window type the following details and then click Next IP Address IP address of VNX File control station. exe which will give you cli access to the storage latest manual can be found here May 10 2016 Storage Processor IP Address 10. And this is done in the pool configuration. To enable the eG agent to monitor the file only storage system s in the VNX Unified storage device the following pre requisites should be fulfilled The storage device should be managed in the eG Enterprise system using the IP address of the Control station that hosts the CLI for file only storage systems EMC VNX. 255. EMC software available from powerlink. Compared to version in the official OpenStack Github master branch here are the enhancements Flare version 5. This changes the immediate configuration but does not persist across restarts. The monitoring of Dell EMC disk arrays relies on the SMI S agent that can be installed on any server that has network access to the Dell EMC disk In the VNX Block Probe Details window type the following details and then click Next Probe Name The probe name must be unique in the Data Center Analytics deployment. I have to use nasadmin user. The EMC SMI S Provider acts like a proxy between vScope and your EMC VNX or Clariion array. Dec 20 2018 esxi iscsi vmware iscsi for dummies netapp for dummies emc netapp openstack unity celerra cinder default dell password vnx centos control station esxcli linux isilon login lun macos onefs rhel Microsoft Windows Server benchmark cisco citrix classic clustered nas copy dell emc eazyBI inode inodes iscsiadm isilon default root password jira ls mac Oct 24 2013 Then just follow the Connection Utility wizard to assign an IP address and host name. xx. The steps require accessing the Control Station CLI through the service port on one of the SPs using a specific IP address 128. Most scenario host would be probably first connected and either auto registered with Host Agent or Unisphere Server Utility or similar software or we would Oct 21 2014 EMC MirrorView configuration on the EMC VNX arrays. xxx SPA IP Address of the CLARiiON VNX array Type xxx. VNX5100 Hardware Information Guide IP address 128. The last section of this guide provides troubleshooting information. Dec 06 2018 You can reassign IP addresses by removing an Isilon node from the network and then readding it. Click System on the toolbar. Password Password123 . Jun 15 2020 An IP address of each VNX block storage processor. VNXe login admin password Page 8 Planning Worksheet IP address for each iSCSI NIC or HBA port iSCSI initiator Server and port Initiator IP address Subnet mask Default gateway Page 9 VNX5300 Assembly Front view of an assembled VNX5300 shown here with a 15 disk DPE and 2 DAEs. What s wrong It needs a lot of resources. On the right hand side you will see link to Manage File LDAP Domain click it. Overall state some agent info like model or serial. This details the problem and states the current fix. 252. Type the IP address for the interface. 0 Thulin 39 Around on vSphere 7. py script confirming that the path to the zabbix_sender command is correct along with the path to the agentd configuration file. An ETA EMC Technical Advisory is a way for EMC to notify customers proactively to address issues such as this before it happens in their environment. emc vnx 5200. xxx. All the information concerning disk arrays storage pools controllers storage volumes and ports as well as EMC Celerra storage systems components such as CIFS Servers CIFS Shares control stations data movers file systems etc. This will shut down the system completely and only the Power Supply s power LEDs will remain on. Table 1. Posted on August 28 2012 by tkrn. Specify the IP address of the storage controller on the block only storage system in the Controller IP text box. Before you use the create subcommand ensure that the etc netmasks file has IP address subnet and netmask entries for all logical hostnames. Prerequisites. September 3 PernixData FVP Freedom Edition Installation and configuration. quot Success quot will be displayed when the SPcollect starts but this only means the script has been started and swindlife emc_vnx version 0. 6. 15 Release Notes doc VASA requires network connectivity between the vCenter server and the Unisphere management ports on the VNX array. Accept Always. 255. The port number at which the storage device listens. The port number at which the storage device listens. Now we need to change the ip addresses of these hosts. 10 lt Hostname SRS server gt . Configuration. 221. 0 Karma. The IP used by DefendX Software Control Audit to contact the VNX must appear in the cepp. Install the ESRS. Page 39 Attach Bezels May 27 2014 Now the laptop will be able to communicate with the management server whose default IP address is 128. Jan 27 2015 26. Once LUN is created you need to assign to the storage group. Upgrade the Splunk Add on for EMC VNX. It is because while generating rsa key I use root. emc. ID. 2 4. SSH v2 is recommended and you may log the session output. 249 Subnet mask 255. 61. conf file. In this case the primary Control station was IP Aug 30 2013 The following command sets the IP address for the default SMTP server that the system will use uemcli d VNXe_IP u Local admin p password net smtp id default set addr 192. The EMC VNX is EMC s Unified mid tier range of storage appliances. Select Power on the VM and click on Finish. On the right pane under Diagnostic Files select 39 Generate Diagnostic Files SPA 39 . The command will prompt you for a Dell EMC Support login and should confirm that the device was successfully registered. If the wrong IP address is used DefendX Software Control Audit will be denied access Pre requisites for Monitoring EMC VNX. xxx. You can retrieve the file from the system using the managefiles command. the VSI is configured to perform unsecure connections. 31. OK here is the list of EMC servers host names IP Feb 25 2015 Select the VNX series array from either the dashboard or from the Systems drop down menu. Login to the Control Station as nasadmin and issue the cmd nas sbin getreason from the CS console. xxx SPA IP Address of the CLARiiON VNX array Type xxx. Oct 07 2001 Type 1 Default for CLARiiON VNX Type xxx. Only local users of VNX File is supported. Edited Feb 17 2019 at 10 09 UTC File EMC VNX Control Station Linux release 3. 21 MB Aug 07 2012 EMC NAS VNX Health Checkup using command line. 3. This series of posts will explain step by step how to do it with CIFS Windows users servers for EMC VNX. If the password is lost you must redeploy the Solutions Integration Service and use the default login ID and password to log in. 0 with support for Microsoft Windows 10 Configuring VMware VASA for the EMC VNX 5200 in vSphere 5. This is more for my reference as I always find myself scratching around for the service LAN IP addresses. 10. This paper. 1 DNS server entries leave blank Sep 01 2018 Fully qualified domain name or IP address of the system where the EMC VNX Storage Provider resides. The Initial Configuration Wizard launches the first time you login. Mar 21 2016 The EMC Storage Analytics ESA management pack integrates the features and functionality of vRealize Operations Manager with a wide range of EMC products. 221. Set your TCP IP network properties to the following IP address 128. 255. 221. 10. com. CLARiiON External Process Timeout for Inventory sec EMC Unity Configuration Guide Overview This guide steps you through configuring your environment to work with an EMC storage platform in preparation for installing Peer Software solutions. EMC VNX systems have 2 storage processors usually suffixed by A or B to denote which one it is. Only local users of VNX File is supported. Specify all the IP address with Target IQN Here you will find IQN of the target storage processor . To start we will need to login with an administrator account such as nasadmin systadmin. Typically the data is replicated every 10 minutes so in worst case scenario using typical setting you will lose up to 10 minutes of users work Mar 07 2012 on the EMC VNX or Clariion you need to create a global login account for the VSS driver to use. emc_nas_server. optional optional Caution Array Software on drives 0 4. If you are using the Unisphere VNX Client local installation add the local file path for your Unisphere client installation directory. The checkup command reports back on the state of the Control Station Data Movers and storage system. On the Ethernet port manually configure the IP and make it something close to the two IP addresses you will be assigning to the VNX. I was curious to see how the VNXe 3300 would pefrorm compared to CX4 240. Explorer. 0. Log in to Unisphere using the default credentials admin Password123 . It is recommended that the IP address of the CEE Server is added to this list. While you Connect make sure you give a Check on Enable Multi path . When adding a system into the domain the system being added will be removed from any of its existing domain configurations. 61. Over the course of a few posts I will start with a fully working Jun 22 2013 What will you tell the storage administrator about the default setting for VNX IP address filtering A. 221. 32. Table 1 121 Supported Status and Performance Metrics for EMC VNX. 10. EMC VNX SERIES UNIFIED STORAGE Max IP Ports per X Blade 8 8 8 12 12 16 . EMC claim this product installs in 2 minutes configures in 15 as one of its key features in this post we ll put that to the test and walk through the setup of an EMC Unity 300 array. 1 7. Prerequisite The XML API server must be enabled on the EMC VNX Control Station. We configured Vnxe 3150 for CIFS fileshare After SMB1 disabled from all clients they are not able to access share using IP address but using hostname is possible Unisphere version 1. Best to post with context when dealing with ancient legacy gear. Under quot Advance quot tab make sure you choose quot Auto quot and this way you don 39 t have to bother about owner of the LUN. Our Operations Team where faced with an unfamiliar situation a few weeks back where we needed to re ip an EMC VNX5300 that had it s warranty extended and was relocated to a new Availability Zone. From VNX Installation Tools download EMC Secure Remote Support IP Client. vScope connects to the SMI S provider and reads the CIM classes provided by it. emc_nas_server The control station IP address of the VNX system to be managed. quot An IP address of the Control Station This data source runs the same commands as the EMC Apr 24 2019 Procedure. The IPv4 netmask may be specified in address attribute after slash. 0 is coming are you ready Dell EMC VxBlock System 1000 Equallogic Storage on One VxBlock to Rule Them All Introducing the VxBlock 1000 Oct 08 2019 Posted Why can I not retrieve vnx file data from EMC VNX 5200 when using Splunk Add on for EMC VNX on All Apps and Add ons. In the Network Mapping step select a destination network that has an IP Pool associated with it for each of the VMs and then click Next. VMware vSphere installation 25 26. zip file on the system. Nov 15 2020 VNX Storage Allocation Naviseccli Commands Generator. Double click EMC CAVA. Connect your laptop via crossover cable to SP Service LAN port. 10. 5 . Port. com and select VNX Series gt Install and Configure. Open communication through network STOR2RRD server storage service processors port 6389 TCP Install Navisphere Secure CLI. At the Name step of the wizard specify the storage system name description and storage role. Storage Pools vs Raid Groups vs MetaLuns From an design perspective MetaLuns were basically replaced by Storage Pools Storage pools allow for the large stripping across many drives that Oct 09 2013 EMC requests that with the VNX 5400 that delayed ACK is turned off we have seen performance improvement when this is done with a Windows physical server connected to the VNX. 11. Enter a username to create. Restart the EMC CAVA service Select the EMC CAVA service. EMC VNX Storage Array . This driver supports Icehouse and newer release. 24. 1. NaviSecCli must be installed on the Cloud Insights AU. No raid groups info by now my VNX didn 39 t have any i 39 ll try to add this feature later. k. Next open the SmartConnect settings and navigate The DefendX Software Control Audit machine s IP address is a critical piece of information. MirrorView is an another EMC replication solution integrated into VNX arrays. VNX SSH Process Wait Timeout sec This data source runs the same commands as the EMC Celerra and EMC CLARiiON. The gateway is the IP address of the router or node used to communicate outside the local subnet. If your EMC file servers use different values for the operatingSystem property you can adjust the search parameters. Click the By default the operating systems of the EMC file servers are set to quot EMC File Server quot and quot EMC Celerra File Server quot in the collector configuration file. xml Computer Jun 14 2016 Book Title. The Navisphere CLI a. Filesystems on your VNX can be backed up using NDMP in emc Networker. All IP address ranges in a pool must be unique. emc_nas_password and emc_nas_login They are the fields that are used to provide credentials to the VNX system. It has 4x1gbit iSCSI per SP 8 ports in total and I 39 d like to get the most out of the performance until we jump over to 10gig iSCSI. Apr 18 2018 Assign different temporary IP address. You will start by clicking on the settings tab. Login using nasadmin and verify the system s health type nas bin nas_checkup. Mar 14 2012 Target host This will be IP address of target Storage Processor or controller . As you know VNX 5500 is active passive storage. To start the XML API server On the VNX Control Station as root uncomment the following Nov 11 2015 Check Pages 1 48 of Configuring Time Services on VNX EMC in the flip PDF version. Type the Address type from step 5 above for both Storage Processors 2 if IP Address 3 if Array ID . xxx. o Enter in the IP address of the SP into a web browser Find the service named EMC CAVA. So you ll open a browser and type in the IP address you assigned it using the connection Utility. Jan 14 2015 In the Windows Control Panel under the Java settings go to the Security tab gt Exception Site List and add the IP Address for the Celerra and or CX VNX you would login to w Unisphere. Jul 12 2017 The IP address of the VNX control station that manages the file side blades. 0. 248 Default Gateway leave blank DNS server entries leave blank . So i have 2 options fix the certs or lower the cert verification checking level. Enter the password associated with the remote user name to connect to the remote system. The default value is 443. Nov 02 2015 The EMC Virtual Storage Integrator VSI for VMware vSphere Web Client is a plug in for VMware vCenter. Enter the name of a user for the remote system who has privileges to create replication connections. The Control Station IP address of the VNX Celerra system. Nov 06 2012 We received a VNX 5300 as a donation in our school district. 221. We have a new VNX5300 waiting to get configured and I need to plan out the network infrastructure before the EMC tech arrives. Inventory Poll Interval min Interval between inventory polls default 40 minutes VNX SSH Process Wait Timeout sec VNX SSH process timeout default 600 seconds Celerra Command Retry Attempts. 1 Click Register. 5. The default is NULL. The Cisco Unified Computing System provides the compute network and storage access Apr 02 2000 EMC Disk Arrays KM for PATROL monitors all your EMC storage assets within a centralized management console. Password EMCPMAdm7n. xxx SPA IP Address of the CLARiiON VNX array type xxx. EMC recommends the Thin provisioned format option when the vApp is deployed in a high performance environment. The EMC Unity product line is a flexible storage solution with a rich feature set and small datacentre footprint. The default is NULL. On the EMC VNX CLARiiON ensure the following Navisphere Unisphere Storage System Initialization Utility is run to initialize Navisphere Unisphere functionality. Controller IP. It is the job of the storage processor to retrieve data from the disk when asked and to write data to disk when asked. i 39 ve attached archive with script and template. com. The fields that are used to provide credentials to the VNX system. Default gateway blank. Step 2. Download zip files that contain the product documentation for the following legacy EMC product lines AX4 5 CX4 and Celerra NS 120 480 960 . If the user MUST supply an IP address they should use nslookup locally and use that IP address. Do not add any disk till the time appliance boots up completely once. 221. config. Stop the Proxy ARP service to return the SPs to the default internal address scheme nas sbin clariion_mgmt stop Let this command run to completion then check SP IPs with ping ping 128. 221. SSH back into VNXe with new IP address and username quot service quot . Dell EMC system configuration requirements Connection type Data source Protocol Default port IP address credential notes Avamar MCSDK API HTTP SOAP 9443 To add a VNX system into an existing VNX local domain in Unisphere navigate to the System List and perform Add operation. 1. 000. 3 255. 1 will appear under Hosts gt Host List as well. Mar 15 2017 Log in to the Control Station as root using SSH. NaviSecCLI is a Command Line Interface CLI used for management diagnostics and reporting functions for VNX. Serial Cable Nov 03 2020 I had a problem on EMC VNX 5200 that was missing connected enclosures the pools whare Stuck and we could not delete any think as the storage was in off line state Solution install NaviCLI Win 32 x86 en_US 7. conf file. Apr 12 2010 Changing IP Addresses on an EMC Celerra NS 960 Published on 12 Apr 2010 Filed in Tutorial 968 words estimated 5 minutes to read Changing the IP addresses on an EMC Celerra unified storage array is generally a pretty straightforward process. View solution in original post. You can only add IP addresses of different physical interfaces. 0 NAS 8. 249 or 128. It has 84 disks a DPE but no CS six 3u DAE and a standby power supply. 1. 168. Have an SSH session to 128. 2. CAVA is one of the few parts of the Celerra VNX that cannot be configured and monitored from the GUI. xxx. dnszone . 110. Description. Processor A IP Address IP address of Processor A of VNX block storage. For manual verification only the IP address of the Unisphere Central server must be configured on EMC VNX series of storage systems are a family of systems that provides unified file and block storage. Port requirements 80 443 Lately I have posted a quick introduction to EMC VNX if you haven t read it yet give it a try EMC VNX Unisphere Quick overview. If default username password is changed enter the credentials of storage administrator role. Aug 22 2011 Configurar o vCenter para utilizar o VASA com o Storage EMC VNX NVLan. Managing VNX Block Storage. 0 NAS 8. Jul 25 2020 Click the Register button select CLARiiON VNX and enter the host name which is the output of the hostname command and IP address Hostname myhost1 IP 10. 45. Then the array is added into Veeam Backup amp Replication and you can use it for Integration for Zabbix and the EMC ECOM server for VNX1 VNX2 Monitoring ktelep EMC Zabbix Integration Oct 12 2016 EMC Unity Setup Guide. 255. xx Repeat for SPB Verify the new information before hitting lt enter gt Feb 19 2016 The correct IP is the same subnet and mask but needs to be changed. xx. The following procedure explains in details how to get install and configure EMC SMI S Provider to enable EMC Disk Arrays KM for PATROL to efficiently interact with it. Now that the VNXe is on the network we can connect to it from the Web UI. EMC supports ZFS in an Oracle Solaris Cluster environment. Specify Storage Name or Address and Storage Role. Enter the network name or IP address of the remote system. The IP Address of the Control Station. EMC VNX iSCSI setup unsure about SP port assignment. 4 Aug 31 2018 There s two IP addresses hiding underneath the black square Or you add them via the CLI using the command ifgroup add default interface lt ip address gt Repeat this command for the additional IP addresses. are directly displayed in your BMC Framework. pdf is the way to go I used version 31. The reason code output should be as follows see detailed list of Reason Codes below Dec 8 19 07 46 emcnas_i0 EMCServer nas_mcd MCD will monitor CS IPMI connection. So let s start You can migrate data from a Celerra or VNX storage system to an EMC Isilon cluster through the isi_vol_copy_vnx tool. The network interface for vmk1 is configured with an IP address on the 17. Next you will need to go to Start gt EMC gt Unisphere Server Utility gt Unisphere Storage System Initialization. Most if not all of the information you need about cava can be found in the command line. Power on the ESXi host. Add the IP of your Storage Leave the Default Port. All in all it took EMC about 8 hours to complete this task under the support agreement. 1. xxx. The VNX is often referred to as the Swiss Army Knife of EMC storage a title that it has rightfully earned in my opinion. 35 For Dell EMC PowerMax and VMAX All Flash PREFACE As part of an effort to improve its product lines Dell EMC periodically releases revisions of its software and hardware. Processor B IP Address IP address of Processor B of VNX block storage. nas sbin navicli h spa security list type. 1. xx Storage Processor Subnet Mask 255. Aug 10 2015 Quick Tip Re IP VNX5300 or any VNX. You have to provide an SP Storage Processor IP address of the VNX system to be added. Couple of months ago I had a chance to play around with VNXe 3300 loaded with 30x300GB SAS drives before it was put on production. Use Credential Policy check box Check if you want to use a credential policy for this account rather than enter the username and password information manually. Jun 21 2018 EMC VNX 5300 How to access Control Station. That 39 s the problem. Mar 15 2012 Rest is self explanatory. Type the Username and Password for a user with admin or manager privileges on the EMC VNX 5100 EMC VNX 5200 EMC VNX 5300 EMC VNX 5500 EMC VNX 5700 EMC VNX 7500. Feb 03 2018 Here are explaining about how we can register the host manually to EMC VNX storage system. Name of the Data Mover to serve the share service. I had already made some peformance testing on the CX4 240 so I had half of the data already 5. Note Java should be installed and available on the system browser . May 05 2021 Select Dell EMC Storage Type gt Adding Dell EMC Unity XT Unity VNXe VNX gt Step 2. Feb 11 2018 Here is a collection of default password to save you time googling for them EMC Secure Remote Support ESRS Axeda Policy Manager Server Username admin. EMC VNXe Unisphere EMC VNXe Series Quick Start Guide step 4 Username admin. Ensure that the user has a Storage Administrator role or higher. 1. If IPv6 is not in use leave the field empty and press Enter to continue. Apr 26 2012 Problems Uninitializing and recreating the VNX Unified File domain for both the Block and File components EMC SW VNX Operating Environment OE for Block 05. If no image is presented continue to the next screen and write down the FTP login detail by default FTP host is the SP IP Address user and password are clariion1992 FROM Windows host gt open CMD gt Jul 15 2009 I was recently configuring an EMC Celerra NS 120FC and using the Celerra Startup Assistant I successfully configured the network settings only to notice after the fact that I had goofed on the IP addresses for the Storage Processors on the backend Clariion. Type 2 Type 2 Type the username type a user that has at least a read access on the CLARiiON VNX Array Type the password password of the above user Then type enter Mar 08 2013 If you want a LAB just run the VNX virtual appliance if its more about emc or a readyNAS random CENTos whitebox with some NFS is honestly easier than cursing at old black box arrays. Nov 17 2011 3. It was tested on VNX5400 and still not as good as I wanted to but still fine. Port. Wait refresh the page and then re enable SSH again. Enter the IPv6 address of the default routing gateway or accept the IPv6 address of the default gateway if the system was able to discover it. You can modify the default IP address pool at any time. Then I had a lightbulb moment that the naviseccli installer had some option about strict cert checking. 221. 1. How do we obtain access and manage it not knowing the IP address passwords or other information Any guidance or advice would be appreciated. These credentials must belong to the EMC VNX storage system Administrator account. 10. Aug 28 2018 karn. vnx_server_container. Yes the VNXe document is publicly available and there is a simple reset button. 252. So you re probably already aware that the best way to connect to the service port is to set your laptop TCP IP settings as follows IP Address 128. 4. Log onto Unisphere confirm IP information for Control Station Log onto Control station via ssh Use root nasadmin default 3. 000. Download zip files of technical content for planning installing replacing and upgrading. 0. Click OK. Port. Access is limited to a single Unisphere client. In the Add Probe window from the Probes list select VNX File. Next you will need to go to Start gt EMC gt Unisphere Server Utility gt Unisphere Storage System Initialization. xxx. Configuring Time Services on VNX EMC was published by on 2015 11 11. Nov 05 2001 Type 1 Default for CLARiiON VNX Type xxx. 10. 1. type 1 Default for CLARiiON VNX type xxx. Big thanks to Sean Thulin for documenting this in a clear and concise fashion and to EMC Support s website for filling in some of the blanks I had via Primus emc308583 . 24. server_ifconfig server_2 create Mar 11 2013 Per the Virtualization for EMC VNX VNX OE for Block 5. Today I would like go to thru the process of creating a Storage Group masking a LUN and connecting a host. Unity nas failover Cisco Catalyst 9300L Network Essentials Switch L3 managed 48 x 10 100 1000 PoE . IPV6 Default Gateway Enter the ipv6 default gateway IP address The virtual machine IP default gateway is configured for the HSRP Virtual IP address and since the HSRP VIP is the same in each Data Center together with the vMAC since the same HSRP group is configured the VM IP default gateway does not need to change and remains active as the VM moves from one Data Center to another. A Services dialog appears confirming that log on rights have been granted. In the example above node 1 has the correct IP address already. A short summary of this paper. 253. 255. Password changeme. The Control Station Port number of the VNX Celerra system. DELL EMC Data Domain Management Center https lt DDMC Name or IP Address gt ddmc . Enter command svc_initial_config a f VNXe3100 n quot 10. extacl 0x00000003 0x00000000 server_2 cifs acl. 0. xxx. Make sure you have enough of disk space on the filesystem where is STOR2RRD installed. Hello everyone. Software. During the configuration process you will be installing and configuring software on the server that will host Peer Software Oct 11 2018 The article contains information on enabling the EMC VNX NAS Gateway Celerra arrays to be monitored by SRM. The ESA delivers custom analytics and visualisations that provide detailed visibility into the EMC infrastructure enhancing troubleshooting and proactively identifying storage performance and capacity issues for remediation. May 29 2014 Reset sysadmin password on VNX. The SPs network properties its IP address subnet mask and default gateway cannot be changed in Unisphere but must be changed through the control station using the steps below. Use a separate Ethernet switch path to the VNX iSCSI Targets Network Portals. 1 EMC VNX for File Simulator If you have two or more network interface ports on the host system you need to configure which network port is going to be assigned to which VMnet port VMnet0 or VMnet2 and which virtual Control Station port eth0 and eth1 . AccessLogix is enabled. Read only Navisphere username and password to the VNX block storage arrays. 254 . If it has 4 ports then you will see 4 IQN. 2 For additional information on using USM go to httpsmydocsemccomVNX 3 Under from IT 375 at Illinois State University Jun 17 2020 We are unable to supply a specific IP address or range of addresses as the IP address is dependent on the location Geo of the DNS server resolving the EMC Online Support host to use. Login to EMC Unisphere accessing MGMT IP Address using Internet browser. This Cisco Validated Design describes how the Cisco Unified Computing System can be used in conjunction with EMC VNX storage systems to implement an Oracle Real Application Clusters RAC solution that is an Oracle Certified Configuration. My thoughts on the lack of LACP in the DD3300 Use the port assignments and IP addresses in the following table to configure the environment for Dell EMC systems. 0. Configure the modular input for the Splunk Add on for EMC VNX. Chapter Title. type 2 type 2 type the username type a user that has at least a read access on the CLARiiON VNX Array type the password password of the above user then type enter EMC VNX Control Station Linux release 3. Gateway address IP address of the default gateway for the management interface. Subnet mask 255. Push the RSA public key to the Control Station for the Splunk Add on for EMC VNX. 168. 61. Follow the steps below to enable AccessLogix Log in to the Navisphere Unisphere console. 221. Add storage into configuration from the UI Settings icon Storage New Vendor device Dell EMC VNX block. 9. The solution leverages the EMC SMI S Provider for CLARiiON and Symmetrix systems that needs to be installed on a Windows or Linux system. 2 via any terminal software like putty. 200 SPA ping 128. OK you have been tasked to configure firewall to allow ESRS server s to connect to EMC servers. Click OK. a. console select which type of array to add VNXe or VNX as well as block or file storage Figure 5 Adding VNX storage as block or file level storage The wizard will only inquire for the Unisphere management IP address as well as a username and password . The LogicMonitor Collector uses this tool to gather data directly from the EMC service processors. emc vnx 5200 default ip address